I. Points for Attention
1. Before the product is installed, please read the operation manual
carefully.
2. The power supply of the product is DC12V/1A.
3. During the transportation, storage and installation, the product should be
avoided from incorrect operations such as heavy pressing, strong vibration
etc., which can cause damage of product as there are sophisticated optical and
electronic devices inside the ball.
4.
Do not attempt to disassemble the camera. In order to prevent
electric shock, do not remove screws or covers. There are no
user-serviceable parts inside.
5.
Always follow all electrical standards for safety when it is in
operation. Adopt the particular power supply, which is provided
with the unit. RS-485 and video signal should keep enough distance
with high voltage equipments and cables when they are in
transmission. Precautions for anti-lightning and anti-surging should
be taken if necessary.
6. The products with plastic shell should be indoor installed and
operated to avoid rain and moisture. Do not use it in wet places.
7. The waterproof grade of metal low speed dome is IP66, and defend-burst.
VII. Troubleshooting
Problem Possible Causes Remedies
No action and images
when power is switched
on
Power supply damaged or
insufficient power
Replace
Wrong connection of
power supply
Correct
Faults in engineering
circuits
Remove
Abnormal
self-inspection. Images
with roaring sound of
the motor
Mechanical fault Repair
Tilting camera Place uprightly
Insufficient electrical
power
Replace with qualified
power supply and let it
close to the ball holder
Normal self-inspection
but no images
Wrong connection of VF
circuit
Correct
Bad connection of VF
circuit
Remove
Camera damaged Replace
Successful
self-inspection but out
of control
Wrong connection of
control signal wire
Correct
Mismatched address Reselect
Mismatched protocol
Adjust protocol to match
with the controller and
switch on again
Images unstable
Bad connection of VF
circuit
Remove